Novatek Electro India Semantic AI Knowledge Base
"RN-111M RN-113 single phase voltage relay textile manufacturing voltage monitoring relay over voltage protection under voltage protection neutral break protection commercial load protection cold storage protection CCTV protection Novatek Electro sp_commercial combo:sp_commercial|industry_spotlight|industry-textile Novatek Electro India"

Single Phase Voltage Relays for Textile Commercial Loads — RN-111M & RN-113

📅 2026-08-31 ✍️ Novatek Electro India 📂 Blog
Single Phase Voltage Relays for Textile Commercial Loads — RN-111M & RN-113

Protect cold storage, CCTV, POS terminals & commercial ACs in textile facilities with RN-111M & RN-113 single phase voltage relays. Adjustable, DIN-rail ready.

Walk into the electrical room of any mid-sized textile manufacturing unit — the kind running a cluster of power looms, dyeing baths and finishing machines — and you will find something telling: a row of burnt MCB boxes, brown scorch marks on contactor terminals, and a maintenance log full of entries that read 'compressor failed — cause unknown.' The cause is almost never unknown to an experienced protection engineer. It is voltage. Specifically, it is the daily rhythm of under-voltage sags during peak production shifts and over-voltage spikes when heavy machinery trips off-load. These events do not announce themselves. They silently degrade insulation, stress capacitor banks, and eventually kill compressors, CCTV DVRs, POS systems and commercial air-conditioning units — the secondary but operationally critical loads that every textile facility depends on.

This article is about protecting those loads — not with expensive power conditioners or UPS banks — but with intelligent, adjustable single-phase voltage monitoring relays that interrupt supply before damage can occur.

The Power Quality Reality in Textile Manufacturing

Textile manufacturing is one of India's most energy-intensive industrial sectors. A typical composite mill or processing unit draws power simultaneously for spinning frames, weaving machines, dyeing vats, compressors and building services. This creates a continuously fluctuating load profile on the incoming supply. The consequences for single-phase commercial loads are predictable and severe.

What Actually Happens on the Factory Floor

  • Under-voltage during peak production: When large three-phase motors start, line voltage on single-phase branches can sag to 170–185 V AC for several seconds. Cold storage compressors and commercial split ACs running in this range draw excess current, overheat motor windings and suffer premature bearing failure.
  • Over-voltage during load shedding: When bulk loads trip simultaneously — a common occurrence during planned or unplanned interruptions — residual EMF and transformer tap mismatches can push single-phase voltage above 260–270 V AC. POS terminals, CCTV DVR power supplies and variable-speed fan drives are particularly vulnerable.
  • Neutral integrity failures: In older textile facility wiring, neutral conductors are often undersized relative to phase conductors. A loose or broken neutral creates voltage asymmetry that subjects single-phase loads to unpredictable, damaging voltage levels.
  • Repeated micro-interruptions: Process-related switching — contactors, solenoids, motorised valves — generates voltage transients that cumulatively stress the SMPS circuits inside CCTV cameras, access control panels and billing terminals.

Against this background, the engineering requirement is clear: every single-phase commercial load in a textile facility needs a dedicated voltage monitoring relay with adjustable trip thresholds, configurable time delays and a contact output capable of switching the load contactor or direct load connection.

Introducing the RN-111M and RN-113: Purpose-Built for Commercial Load Protection

Novatek Electro's RN-111M and RN-113 are DIN-rail mounted single-phase voltage monitoring relays designed for exactly this class of application. Both models monitor the incoming 220–240 V AC single-phase supply continuously and de-energise their output contact whenever voltage falls outside the configured window or a neutral break condition is detected.

RN-111M — 16 A Single Phase Voltage Monitoring Relay

Novatek Electro RN-111M Single Phase Voltage Monitoring Relay
ParameterSpecification
Voltage TypeAC
Supply / Monitoring Voltage220–240 V AC
Number of Poles2 Pole
Rated Current16 A
Contact FormSPDT (1NO + 1NC)
Protection FunctionsUnder-voltage, Over-voltage, Neutral break
MountingDIN Rail
BrandNovatek Electro
Price (ex-GST)Rs. 2,000 per piece

At 16 A rated current with an SPDT output, the RN-111M is suited for directly switching smaller single-phase commercial loads — CCTV system distribution boards, POS terminal power strips and light commercial refrigeration units — where the load current stays within the relay's own contact rating.

Buy RN-111M — Rs. 2,000

RN-113 — 32 A Single Phase Voltage Monitoring Relay

Novatek Electro RN-113 Single Phase Voltage Monitoring Relay
ParameterSpecification
Voltage TypeAC
Supply / Monitoring Voltage220–240 V AC
Number of Poles2 Pole
Rated Current32 A
Contact FormSPDT (1NO + 1NC)
Protection FunctionsUnder-voltage, Over-voltage, Neutral break
MountingDIN Rail
BrandNovatek Electro
Price (ex-GST)Rs. 2,875 per piece

The RN-113 steps up the contact rating to 32 A, making it the correct choice for driving contactors feeding commercial split ACs, small passenger or goods lifts, and walk-in cold storage units where compressor start currents demand a higher-rated switching path.

Buy RN-113 — Rs. 2,875

Why These Protection Features Matter in Textile Environments

Adjustable Voltage Window

Both relays allow the operator to set independent upper and lower voltage thresholds. In a textile facility where the utility supply can swing between 190 V and 265 V AC across a working day, being able to define a tight window — say 210 V to 250 V — means the relay trips before the load enters a damaging operating region, not after the damage is done.

Time Delay on Trip and Reconnect

Configurable time delays are not a convenience feature — they are an engineering necessity. A cold storage compressor cannot be restarted immediately after a fault clearance; the refrigerant needs time to equalise pressure across the compressor valves. A reconnect delay of 2–3 minutes prevents the compressor from attempting to restart against full head pressure, which would trigger the thermal overload and potentially cause valve damage. Similarly, a trip delay filters out momentary sags that would otherwise cause nuisance tripping of CCTV systems and POS terminals during heavy motor starts.

Neutral Break Detection

In older textile facility wiring, neutral breaks are a known failure mode. When the neutral is lost, single-phase loads can see voltages far above their rated levels depending on the load distribution on the three phases. Both the RN-111M and RN-113 include neutral break protection, which immediately opens the output contact under this condition — protecting connected equipment from an overvoltage event that a standard fuse or MCB would not catch in time.

SPDT Contact Output for Contactor Integration

The SPDT (1NO + 1NC) contact configuration allows both relays to be integrated into standard contactor control circuits. The NC contact can drive an alarm or indicator, while the NO contact feeds the contactor coil. This is particularly relevant for commercial ACs, cold storage systems and small lift motor control panels where contactor-based load switching is already the norm.

Application Mapping: Which Relay for Which Load

Cold Storage Units in Textile Warehousing

Walk-in cold rooms and chest freezers used for storing dye chemicals, adhesives or temperature-sensitive fabric finishes are compressor-driven loads highly sensitive to under-voltage. For cold storage applications with single-phase supply, the RN-113 (32 A) is recommended to handle the contactor switching for the compressor motor circuit, with the reconnect delay set to protect against short-cycle starts after voltage restoration.

CCTV Surveillance Systems

Textile manufacturing facilities typically run large CCTV networks covering production floors, warehouses and entry points. The DVR units, NVRs and PoE switches that form the backbone of these systems contain sensitive SMPS power supplies that are vulnerable to over-voltage. The RN-111M (16 A) is well-suited for protecting the distribution board feeding CCTV infrastructure, disconnecting supply during over-voltage events and reconnecting after a configurable delay.

POS and Billing Terminals

Factory outlet stores, fabric showrooms and canteen billing counters within textile complexes use POS terminals, barcode scanners and receipt printers — all SMPS-fed loads with tight voltage tolerances. The RN-111M provides cost-effective protection for these loads, with the upper trip threshold set to disconnect supply before the over-voltage reaches the terminal's power supply clamping voltage.

Commercial Split Air Conditioners

Office spaces, sample rooms and quality control laboratories within textile facilities are typically air-conditioned with commercial 1.5–2 tonne split units. These units draw 7–12 A at rated load, and their inverter drive boards are sensitive to both under-voltage and voltage transients. The RN-113 is recommended for AC circuits where the contactor and control wiring need to accommodate the compressor's starting current envelope.

Small Passenger and Goods Lifts

Single-phase small lifts — common in two- or three-floor textile office blocks and showrooms — present an interesting protection challenge. The lift control panel already includes a contactor; the RN-113's 32 A SPDT output can be wired into the lift controller's supply circuit to inhibit operation during under-voltage conditions that would cause the lift motor to stall or overheat.

Quick Selection Guide

ApplicationRecommended ModelCurrent RatingPrice (ex-GST)
Cold storage compressor contactor controlRN-11332 ARs. 2,875
CCTV distribution board protectionRN-111M16 ARs. 2,000
POS terminal and billing counter powerRN-111M16 ARs. 2,000
Commercial split AC contactor circuitRN-11332 ARs. 2,875
Small lift supply protectionRN-11332 ARs. 2,875

Relevant Standards and Compliance References

Engineers specifying voltage monitoring relays for commercial and industrial applications in India should be aware of the following standards:

  • IS 12360: Voltage bands for equipment operating on 230/400 V AC supply — defines the ±10% steady-state voltage tolerance that utility supplies are expected to maintain, and within which connected equipment must operate safely.
  • IEC 60255-1: Measuring relays and protection equipment — general requirements, covering relay accuracy, response times and environmental performance.
  • IEC 60947-5-1: Low-voltage switchgear and controlgear — control circuit devices and switching elements, applicable to the SPDT output contacts of monitoring relays used in contactor control circuits.
  • IS 732 / IEC 60364: Electrical installations of buildings — relevant to wiring practices and protection coordination in commercial premises within textile facilities.
  • Bureau of Energy Efficiency (BEE) guidelines for commercial ACs — specify minimum supply voltage requirements that map directly to the under-voltage trip thresholds configurable in both relays.

Why Novatek Electro?

  • ISO 9001:2015 certified manufacturing: Every RN-111M and RN-113 unit is produced under a documented quality management system, ensuring consistent relay performance and contact reliability across production batches.
  • CE certified: Both models carry CE marking, confirming compliance with relevant European directives for electrical safety and electromagnetic compatibility — a meaningful benchmark for product design discipline even in the Indian market.
  • Made in India: Manufactured at Novatek Electro India Private Limited's facility in Delhi, with local supply chain accountability and faster spare availability through a national distributor network.
  • 30+ years of protection relay expertise: Novatek Electro's parent organisation has over three decades of focused experience in electrical protection devices — this is not a diversified electronics company that incidentally makes relays.
  • Accessible after-sales support: Technical queries are handled directly, with datasheet documentation, wiring diagrams and application guidance available through authorised channels — critical for panel builders and OEMs integrating these relays into custom panels.
Ready to specify the right voltage relay for your textile facility's commercial loads?
Both the RN-111M (Rs. 2,000 ex-GST) and RN-113 (Rs. 2,875 ex-GST) are available for online purchase through Intelli-Electro, Novatek Electro's authorised e-commerce platform. For bulk procurement, OEM pricing or panel-builder accounts, contact the sales team directly.

Shop RN-111M & RN-113 Online Email: sales@novatek-electro.in Call: +91-7840054744

Frequently Asked Questions

Q: What is the difference between the RN-111M and the RN-113, and how do I choose between them?
A: The primary difference is the rated output contact current: the RN-111M is rated at 16 A while the RN-113 is rated at 32 A. Both provide identical protection functions — under-voltage, over-voltage and neutral break detection — on a 220–240 V AC single-phase supply with a 2-pole, SPDT (1NO + 1NC) contact form. Choose the RN-111M for loads or contactor coil circuits where the switched current stays within 16 A. Choose the RN-113 for heavier loads such as cold storage compressor contactors, commercial AC circuits or small lift supply panels where switching currents can reach 32 A.
Q: Can the RN-111M or RN-113 directly switch a 1.5-tonne split AC compressor, or does it need to go through a contactor?
A: A 1.5-tonne split AC typically draws 6–8 A at full load, which is within the RN-111M's 16 A contact rating. However, for best practice and to avoid welding relay contacts during compressor start inrush, it is recommended to use the relay's SPDT output to control a dedicated single-phase contactor, especially if the AC will start under load or if the circuit also carries auxiliary loads. The RN-113 at 32 A provides a more comfortable margin for direct contactor coil switching in 2-tonne-and-above applications.
Q: What voltage thresholds should I set for protecting a cold storage compressor in a textile facility?
A: For single-phase cold storage compressors, a typical starting point is an under-voltage trip at 200–205 V AC and an over-voltage trip at 255–260 V AC. This provides a ±10% window around the 230 V nominal — consistent with IS 12360 supply voltage band requirements. The exact thresholds should be refined based on the compressor manufacturer's specified operating voltage range, which is usually printed on the motor nameplate. Set the reconnect delay to at least 3–5 minutes to allow refrigerant pressure equalisation before restart.
Q: Does neutral break protection in the RN-111M and RN-113 work even if the voltage appears normal at the time of the neutral fault?
A: Yes. The neutral break protection function is designed to detect the loss of neutral continuity independently of the instantaneous voltage reading. In a neutral break condition on a three-phase system, the phase-to-earth voltage seen by single-phase loads can momentarily appear within normal range before shifting dramatically, depending on the load mix. The relay's neutral break detection circuit monitors the neutral reference directly and trips the output contact as soon as the neutral path is compromised, without waiting for an out-of-range voltage condition to appear.
Q: Are the RN-111M and RN-113 suitable for DIN-rail mounting inside standard electrical panels?
A: Yes. Both models are designed for standard 35 mm DIN-rail mounting, making them fully compatible with conventional distribution boards and motor control panel layouts used in commercial and light industrial installations across Indian textile facilities. Their compact 2-pole form factor allows multiple units to be mounted side by side within a standard panel enclosure.
Q: What happens when the voltage returns to normal after a fault — does the relay reconnect automatically?
A: Yes, both relays reconnect automatically after the supply voltage returns within the configured window and the set reconnect time delay has elapsed. This automatic reconnect behaviour is important for unattended commercial loads such as cold storage and CCTV systems where manual intervention after every voltage event is impractical. The reconnect delay can be adjusted to suit the specific load type — longer for compressors, shorter for electronic loads.
Q: Can I use the RN-113 for a CCTV system that runs 24 hours a day, 7 days a week?
A: Yes, both the RN-111M and RN-113 are designed for continuous duty operation on 220–240 V AC supply. For CCTV applications, the RN-111M's 16 A rating is generally more than adequate since typical CCTV DVR and NVR systems draw well under 5–6 A. The RN-113 would be appropriate only if the CCTV distribution board also feeds other higher-current loads and a single higher-rated relay is preferred for the consolidated circuit. Set the over-voltage trip threshold conservatively — around 245–250 V — to protect sensitive NVR power supplies from even moderate over-voltage excursions.
Q: How do these relays handle rapid voltage fluctuations without causing nuisance trips on POS terminals?
A: The configurable trip time delay is the key tool for avoiding nuisance tripping. For POS terminals and billing systems, set the trip delay to 1–3 seconds. This filters out momentary voltage dips caused by motor starts or load switching elsewhere in the facility, which typically recover within one to two cycles. Only sustained under-voltage or over-voltage conditions lasting longer than the set delay will cause the relay to trip, preventing unnecessary interruption of transaction processing.
Q: What is the price of the RN-111M and RN-113, and does that include GST?
A: The RN-111M is priced at Rs. 2,000 per piece and the RN-113 at Rs. 2,875 per piece, both exclusive of GST as per the 2026–27 price list effective 01 April 2026. GST at 18% is applicable additionally. For bulk orders, panel builders and OEMs should contact the Novatek Electro sales team to inquire about volume pricing and trade account arrangements.
Q: Are there any IS or IEC certifications I should ask for when specifying these relays for a commercial installation?
A: Both the RN-111M and RN-113 are CE certified products manufactured under ISO 9001:2015 quality management certification by Novatek Electro India Private Limited. For Indian commercial installations, the relevant design and application standards are IS 12360 (supply voltage bands), IEC 60255-1 (measuring and protection relays) and IEC 60947-5-1 (control circuit devices). Always request the product datasheet and declaration of conformity from your distributor or Novatek Electro directly when preparing specification documents for audits or regulatory submissions.
Q: Can the NC contact of the SPDT output be used to trigger an alarm or indicator light when voltage goes out of range?
A: Yes. The SPDT (1NO + 1NC) contact configuration is specifically useful for this purpose. Under normal operating conditions, the relay is energised and the NO contact is closed (powering the load or contactor coil) while the NC contact is open. When a fault condition occurs, the relay de-energises: the NO contact opens (disconnecting the load) and the NC contact closes, which can be used to complete an alarm bell circuit, illuminate a fault indicator lamp or send a signal to a building management system input. This dual-contact arrangement allows simultaneous load disconnection and fault annunciation from a single relay.
Q: Is the RN-113 appropriate for protecting a single-phase small goods lift in a textile facility?
A: Yes. For small single-phase goods lifts — typically found in two- or three-floor fabric warehousing or showroom blocks — the RN-113's 32 A contact output is appropriate for insertion into the lift controller's single-phase supply circuit. The relay should be wired so that voltage faults cause an orderly supply disconnection. Set the under-voltage trip threshold to match the lift motor's minimum specified operating voltage (typically 200–210 V AC) and the reconnect delay sufficiently long to allow any control logic to reset before supply is restored. Always consult the lift manufacturer's wiring guidelines before modifying the control panel.
Q: Where can I buy the RN-111M and RN-113, and is online purchase available?
A: Both models are available for online purchase through Intelli-Electro at intelli-electro.com, which is the authorised e-commerce platform for Novatek Electro products in India. For trade accounts, bulk procurement or technical pre-sales support, you can also reach the team at sales@novatek-electro.in or call +91-7840054744 during business hours.
Q: What wiring topology should I use when installing the RN-111M in series with a distribution board feeding multiple POS terminals?
A: The recommended approach is to wire the RN-111M as a voltage monitoring relay controlling a single-phase contactor, rather than passing the full load current through the relay's own contacts. Connect the relay's monitoring terminals to the incoming phase and neutral; wire the relay's NO output contact in series with the contactor coil. The contactor then controls the power feed to the POS distribution board. This topology keeps the relay's contacts lightly loaded (contactor coil current is typically below 1 A), extending contact life significantly and allowing you to use a contactor appropriately rated for the total POS panel load current.
Tags: "RN-111M RN-113 single phase voltage relay textile manufacturing voltage monitoring relay over voltage protection under voltage protection neutral break protection commercial load protection cold storage protection CCTV protection Novatek Electro sp_commercial combo:sp_commercial|industry_spotlight|industry-textile Novatek Electro India"
Share this article
WhatsApp LinkedIn Twitter/X

Related Articles

Multifunction Time Delay Relays REV-120, REV-114, REV-201M for Oil, Gas & Petrochemical Automation
Multifunction Time Delay Relays REV-120, REV-114, REV-201M for Oil, Gas & Petroc
2026-09-09
Single Phase Voltage Relays for Hotel Pump Protection — RN-119 & RN-102
Single Phase Voltage Relays for Hotel Pump Protection — RN-119 & RN-102
2026-09-06
Overload Relays & Power Controllers for Food Processing & Cold Chain
Overload Relays & Power Controllers for Food Processing & Cold Chain
2026-09-03